19
F232085
Mechanical Installation
Mounting Bolt Installation
A bolt kit is available as an option. The UW35 uses
5/8-11 x 6 inch bolts; the UW60 uses 3/4-10 x 8 inch
bolts. The bolts should be embedded in a 3500 psi
minimum reinforced concrete floor that is a minimum
of 6 inches (15 cm) thick. For mounting bolt layouts
for both machines, refer to Figures 3 and 4. (The front
of the washer-extractor is the bottom of the diagram.)
NOTE: Make sure that all provided mounting bolts
are used to mount the machine to the floor.