Vista de página 14
Cod. G522433
© Copyright 2009, Alliance Laundry System LLC – DO NOT COPY OR TRANSMIT Rev. 00/0510
Transportation and location 15
fig. 7
2.4. Installing more than one washer
If the installation calls for more than one washer, align them with each other.
The minimum distance between adjacent machines and the areas of use and maintenance (values I, S and T
of fig. 7) are specified on the attached table.
Check the dimensions of the drain box and the drain pipe on the table below.
Location specifications (fig. 7)
I DISTANCE BETWEEN MACHINES (MINIMUM) mm (inch.)
700 (27.6)
S WORKING AREA mm (inch.)
1000 (39.4)
T REAR MAINTENANCE AREA
mm
(inch.)
750 (29.5)
A DRAIN BOX
mm
(inch.)
400 x 400 x 300 (H)
(16 x 16 x 12 H)
DRAIN PIPE
(x1; x2; x3)
mm
(inch.)
180; 250; 360
(7; 10; 14)